A research instrument that we house is not molded. It starts as flat sheet that is CNC machined, scored with V-grooves, folded on a thermal bender and solvent bonded, and each of those steps has dimensions it holds well and a few things it cannot do. Design to those limits from the first sketch and the engineering review becomes a check instead of a redesign.
Below is the rule set our engineers apply to research devices, in the order the decisions come up, with the numbers. The general version is our plastic enclosure design guide; this one is applied to instruments that are opened often, revised between builds and wiped down on a bench.
Dimension to the inside walls
Every dimension on a bent enclosure is taken to the inside walls. The outside grows by one material thickness at each bend, so a U-shaped body in 3 mm ABS with 150 mm between its inside walls measures 156 mm across the outside, and the same body in 6 mm sheet measures 162 mm.
Model the contents first, at real size: boards, display, sensor heads, battery, and the bend radius of every cable leaving a connector. Research devices tend to gain a board or a connector between builds, so leave margin in the direction the design is likely to grow. Widening a fabricated body later is a program edit, not a new mold, but a body that already fits the next revision still saves a prototype cycle.
Choose the sheet and gauge before the flat pattern
In a sheet enclosure, wall thickness is a gauge chosen per piece, not a feature dimension. General-purpose ABS is stocked in 3, 4, 6 and 8 mm. Three millimeters suits most bench and handheld housings; 4 to 8 mm goes where a long span needs stiffness or a base carries a pump or transformer. Our average enclosure is eight pieces in two thicknesses. Long bends in 6 mm sheet tend to warp, so keep thick sheet to flat panels and short bends where you can.
Settle the flame rating now, because it narrows the choice. If the device needs a UL94 V-0 housing, the stocked options are flame-retardant Royalite ABS, in 3 mm black or white, and Boltaron 4335. Ask before thickening a V-0 wall; ribs or corner doublers may be the simpler answer. The materials page lists every stocked sheet with its data sheet.
Split the body into flat patterns
Decide which faces fold from one sheet and which are separate bonded pieces. The V-groove is cut on a table saw and runs the full width of the panel, so one sheet cannot fold up on four sides the way a brake press makes a tray. A box is bent sections plus bonded end pieces, and no sheet carries bends in two directions. Fewer pieces and more bends means less machining and fewer bonded joints.
Keep machining on one side of each sheet. Reverse-side features need a second setup in a template, which doubles the labor on that piece and holds ±0.4 mm to the front instead of ±0.2 mm. The limits that shape the flat pattern:
| Rule | Limit | What it means in the model |
|---|---|---|
| Standard bend | Up to 115° | A sloped display face folds from the same sheet as the top or front |
| Reverse bend | Up to 45° | Shallow offsets and steps, not a folded-back wall |
| Bend length | 40 in maximum | Longer bodies are joined pieces or a frame |
| 90° bend radius | Square inside, one thickness outside | Inside corners are crisp; allow for the outside radius in clearances |
| Bends under 90° | Bending cut is visible | Close the ends with caps or end plates |
| Curves | Rolled in one direction | A front can roll into the top; no domes |
| Machining tolerance | ±0.2 mm on the flat pattern | Features on one face hold position to each other |
| Edge radii | 1, 2 or 3 mm standard | Maximum 2 mm on 3 mm sheet; leave a flat land for the router bearing |

Hold critical alignments within one panel
Research hardware usually has one relationship that matters more than the rest: an optical port in line with a sensor, a sample slot in line with a carriage, an electrode jack field that has to match a cable assembly. Keep those features in one flat pattern, machined from one side, where they come from the same program at ±0.2 mm. Every bend or bonded joint between two features adds to the stack.
Better still, mount the critical part to the panel that carries its opening, on brass inserts in that panel, instead of to the base. The alignment then depends on one machined sheet, and the bends only hold the box together. Because each feature comes from a CNC program and not an operator’s setup, the alignment you approve on the prototype repeats on later builds.
Place seams for cleaning and keep them out of tension
Joint lines cannot be hidden, so decide where they go. The tongue is 1.8 mm wide by 1 mm deep in a groove 2 mm wide by 1.2 mm deep, sized for a net fit with a nominal 0.2 mm clearance, and a 0.5 mm chamfer on the tongue edge turns the seam into a deliberate line. On an instrument that is wiped with disinfectant, put seams on edges and corners, not across the touch surface or the area under a sample port. Our post on designing medical enclosures for cleaning and service covers seam placement in detail.
Structurally, no solvent joint should be loaded in tension. If a handle, a probe holster or a wall bracket pulls on a panel, carry that load through a bend or through fasteners into brass inserts, not across a bonded seam that can peel. You do not need to model the tongues and grooves; we add them, with the bend allowances, during the review.
Bosses and inserts: count how often it opens
The fastener choice turns on how many times a screw goes in and out. Self-tap bosses suit screws driven once or twice in the product’s life and need at least 4 mm of thread depth. Brass inserts, heat-staked into bosses, suit anything serviced. Research instruments tend to be opened often, for a firmware cable, a board swap or a recalibration, so treat every lid and access panel as serviced and self-tap only the parts mounted once.
- Keep bosses under 9 mm tall. A taller support becomes a sidewall tab or a frame.
- Combine bosses wherever two parts can share one.
- Stacked male/female hex standoffs need brass inserts.
- Key parts so they assemble only one way, with different boss diameters or one-way tabs.
- A slide-in door without fasteners needs a frame or an undercut, and a good snap is hard to make in sheet, so most doors use a fastener into an insert.
Insert heights and the standard hardware options are on the functional features page.
Openings: vents, windows and pockets
Openings are machined into the flat sheet before bending, which is where most of the process’s flexibility comes from.
- Vents: slots rather than holes, 2 mm minimum width, with cross supports left in so the wall stays rigid. Keep the pattern as open as the wall allows and match fan inlet area to outlet area.
- Windows: acrylic bonds into a recess from the rear, flush with the front or recessed with a chamfer. Polycarbonate does not solvent bond, so a polycarbonate window mounts behind a bezel.
- Pockets: above about 9 square inches, a through-cut with an insert bonded from the back costs less than a machined pocket and leaves no machine marks.
- Keypads and labels: allow 0.010 in clearance per side around a keypad insert, and use labels or overlays at least 0.015 in thick in a recess so they hide the machining.
- Feet: recess rubber feet into machined pockets so they do not creep across the panel over time.
What to send for review
Send the enclosure as a solid with the walls, openings and hardware you need, in STEP, IGES, SAT, SolidWorks, STL or DXF, and leave out the joint details. An engineer checks the model against the rules above, adds tongues, grooves, bend allowances and flashing, and returns a 3D model for your approval before any sheet is cut. If you have no CAD, the board, a connector list and a sketch are enough to start.
Upload your model or sketch on the CAD file page. An engineer replies within one business day, with any rule the design breaks marked up and the fix for each.